A
- Adjudication#
- Labeling
Adjudication is the step where a third, usually senior, reviewer settles cases on which independent labelers disagree. It produces one final label per item and records why the disagreement was resolved that way.
- Annotation guideline#
- Labeling
An annotation guideline is the written rulebook labelers follow: the label definitions, how to apply them, and how to handle edge cases. A clear guideline is the main way to make labels consistent across people and over time.
- AUROC#
- Evaluation
AUROC (area under the receiver operating characteristic curve) summarizes how well a model ranks positive cases above negative ones across all thresholds. A value of 0.5 is no better than chance and 1.0 is perfect separation.
B
- Benchmark vs custom eval#
- Evaluation
A benchmark is a fixed public test set used to compare many models, while a custom eval is built for one product's intended use, users and data. Benchmarks are good for comparison, but a custom eval is usually needed to show a model works for a specific clinical task.
C
- Calibration#
- Evaluation
Calibration is how closely a model's predicted probabilities match observed outcome rates; for example, among cases given 20% risk, about 20% should have the outcome. A model can rank cases well (high AUROC) and still be poorly calibrated. Not to be confused with rater calibration, the training rounds that align labelers to the guideline.
Related - Clinical prediction model validation#
- Evaluation
Clinical prediction model validation tests whether a model that estimates a patient's risk or diagnosis performs well on data it was not developed on. It typically reports discrimination (such as AUROC) and calibration, ideally on external data.
Related - Clinical reasoning traces#
- Labeling
Clinical reasoning traces are written, step-by-step explanations of how a clinician moves from findings to a diagnosis or decision. They are used to train and evaluate AI models on the reasoning process, not only the final answer.
Read the guide · Related method
Related - Cohen's kappa#
- Labeling
Cohen's kappa measures agreement between two raters on categorical labels after correcting for the agreement expected by chance. A value of 1 means perfect agreement and 0 means agreement no better than chance, and negative values mean worse than chance.
- Consensus labeling#
- Labeling
Consensus labeling assigns each item a final label by combining the judgments of several labelers, for example by majority vote or a joint discussion. It reduces the effect of any one person's errors or biases.
D
- DICOM#
- Labeling
DICOM (Digital Imaging and Communications in Medicine) is the international standard file format and network protocol for medical images such as CT, MRI and X-ray. DICOM files carry header metadata, which can include patient identifiers that must be handled before images are shared.
E
- EC57#
- Labeling
EC57 is the ANSI/AAMI standard for testing and reporting the performance of heart rhythm and ST-segment measurement algorithms on reference ECG databases. It specifies how algorithm output is compared beat by beat with reference annotations.
F
- Fleiss' kappa#
- Labeling
Fleiss' kappa extends chance-corrected agreement to multiple raters, typically three or more, labeling the same items. It is used when each item is rated by a fixed number of raters who need not be the same people.
I
- Inter-rater agreement#
- Labeling
Inter-rater agreement is how consistently different people assign the same label to the same item. It is reported with statistics such as percent agreement, Cohen's kappa or Fleiss' kappa, and low agreement often signals an unclear guideline or a hard task.
L
- LLM-as-a-judge#
- Evaluation
LLM-as-a-judge uses a large language model to score or compare other models' outputs against a rubric. It scales evaluation, but its scores should be checked against expert human ratings because judge models have known biases.
Related - Local validation#
- Evaluation
Local validation tests an AI tool on a site's own patients, data and workflow before or after deployment. Performance often changes between sites, so results reported elsewhere may not carry over.
M
- MRMC reader study#
- Evaluation
An MRMC (multi-reader, multi-case) study has several clinicians read the same set of cases, typically with and without AI, to measure the tool's effect on reader performance. Its design accounts for variation both between readers and between cases.
P
- Preference data#
- Labeling
Preference data records which of two or more AI responses a human judges better, sometimes with reasons. It is the main input for training reward models in RLHF and for comparing models side by side.
Related
R
- Red teaming#
- Evaluation
Red teaming is deliberate adversarial testing in which people try to make an AI system produce unsafe, wrong or harmful outputs. In health AI it probes failures such as dangerous advice, missed emergencies or leaked private data.
- Reference standard (gold standard)#
- Labeling
A reference standard is the best available determination of the true answer, against which labels or model outputs are scored. In medicine it is often expert consensus, pathology or follow-up outcome, and it is called a gold standard when treated as definitive.
- RLHF#
- Labeling
RLHF (reinforcement learning from human feedback) trains a model to produce outputs people prefer, using human rankings or ratings of its responses. Typically a reward model is fit to that preference data and the language model is then optimized against it.
S
- Sensitivity and specificity#
- Evaluation
Sensitivity is the share of true positive cases a test correctly flags, and specificity is the share of true negative cases it correctly clears. Changing a model's threshold usually trades one against the other. Sensitivity is also called recall; PPV is also called precision or positive predictivity (+P).
- Sensor accuracy validation#
- Evaluation
Sensor accuracy validation compares a wearable or device measurement, such as heart rate or blood oxygen, against a reference method in the same people at the same time. Results are reported with agreement measures such as mean error and limits of agreement.
- Subgroup performance audit#
- Evaluation
A subgroup performance audit measures a model's accuracy separately for groups such as age, sex, race or ethnicity, and device type. It reveals cases where good overall performance hides poor performance for some patients.
T
- Test set sample size#
- Evaluation
Test set sample size is the number of cases needed to support a decision about a performance metric. It is sized either for precision (a confidence interval narrow enough around the estimate) or for power (enough cases to show the metric beats a pre-set threshold at a chosen alpha and power). Either way it depends on the metric, its expected value and how common the condition is.
W
- Wear time and missingness#
- Evaluation
Wear time is how long a wearable was actually worn, and missingness is the data gaps caused by non-wear, charging or signal loss. Both must be measured and reported, because gaps that are not random can bias results.
No terms match.
Working on a medical AI dataset or evaluation?
Tell us about your project and we'll follow up.
Book a consult