Compare and decide
What Does a HIPAA App Review Actually Check? Inside a Fabrica Assessment
Last reviewed: . Vendor facts checked against each vendor's own pages on the dates shown.
Short answer: A HIPAA app review checks where patient data travels in your app and whether each stop is protected: a BAA with every vendor that touches PHI, access limited by role, logged record access, no exposed keys, and a documented risk analysis. (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026) Before any review, including a Fabrica assessment, list every service your app uses and where patient data goes.
You built a practice app with an AI app builder or coding agent, and someone (your partner, your privacy officer, or you) now wants it reviewed before real patients use it. The word review covers very different things: a quick look at the database, a penetration test (a hired tester trying to break in), a risk analysis, or a check of every change before it goes live. This page lays out what a HIPAA-focused review of a vibe-coded app actually looks at, the rule or vendor document behind each check, and exactly what happens in a Fabrica assessment and what does not.
We make Fabrica, so weigh this page with that in mind. Regulatory and vendor statements are cited and dated, and we say when another kind of review fits better. This is not legal advice. Your counsel or privacy officer decides what your practice needs.
What HIPAA and your vendors say a review has to look at (checked November 15, 2026)
The rule: a risk analysis, and the safeguards it tests
A HIPAA review of an app ties back to one Required item in the Security Rule (the federal rule for electronic patient data):
“(A) Risk analysis (Required). Conduct an accurate and thorough assessment of the potential risks and vulnerabilities to the confidentiality, integrity, and availability of electronic protected health information held by the covered entity or business associate.”
For an app, that analysis turns into a short list of technical questions:
- Access control. Only people or programs granted access can reach ePHI (electronic protected health information). (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026) Each user needs a unique ID, and an emergency access procedure is also Required. (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026)
- Audit controls. Systems holding ePHI need mechanisms that record and examine activity, (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026) and someone must regularly review those records (Required). (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026)
- Proving who is signing in. The rule requires procedures to verify that a person or entity seeking access to ePHI is the one claimed. (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026) In a vibe-coded app, a reviewer looks for one shared front-desk login, test accounts left active with simple passwords, and sign-in links that anyone holding a forwarded email can use. Each one weakens the proof of who opened a record.
- Integrity. Policies and procedures must protect ePHI from improper alteration or destruction. (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026) For an app changed by an AI agent, that means asking what stops a generated database change from deleting or rewriting patient rows, and whether anyone would notice if it did.
- Transmission security. ePHI sent over a network must be protected against unauthorized access. (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026)
- Minimum necessary. Reasonable efforts to limit PHI to what the purpose needs. (HHS (eCFR), 45 CFR 164.502 -- Uses and disclosures of protected health information: General rules., verified November 15, 2026)
- Agreements. A vendor may handle PHI for you only if you get satisfactory assurance that it will safeguard it, (HHS (eCFR), 45 CFR 164.502 -- Uses and disclosures of protected health information: General rules., verified November 15, 2026) documented in a written agreement, which is the business associate agreement (BAA). (HHS, 45 CFR 164.502 -- Uses and disclosures of protected health information: General rules., verified November 15, 2026) A vendor's own subcontractors that handle PHI are business associates too. (HHS (eCFR), 45 CFR 160.103 -- Definitions., verified November 15, 2026)
- Re-checking after changes. Periodic evaluation, including in response to operational changes affecting ePHI security. (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026) If you change your app every week with an AI tool, each change is a reason to look again.
The vendors: their own documents say where apps leak
- Supabase, a hosted database service, puts it plainly: “A table in an exposed schema without RLS is readable and writable by any role with a grant on it. Enable RLS on every table in an exposed schema.” (Row Level Security | Supabase Docs, verified November 15, 2026) RLS (Row Level Security) is the set of database rules that decide which rows each user can read. Supabase's Security Advisor flags a public table without it as an error-level finding. (Performance and Security Advisors | Supabase Docs, verified November 15, 2026) It also says secret and service role keys (master keys for the database) are never safe to expose, because they bypass RLS. (Securing your data | Supabase Docs, verified November 15, 2026) And under Supabase's BAA, the customer alone is responsible for those row rules, key management and sign-in settings:
“Customer is solely responsible for application-level access controls, including Row Level Security policies, API key management, user authentication configurations, and all other Customer-controlled configurations identified in the Shared Responsibility Model.”
- Vercel advises keeping development, staging and production separate so PHI never reaches a preview or test deployment outside your controls, (How to build and maintain HIPAA-compliant applications on Vercel, verified November 15, 2026) and its runtime logs include console.log output (the debugging lines code prints) from both preview and production. (Vercel, Runtime Logs, verified November 15, 2026)
- AI model providers. OpenAI's HIPAA guide says PHI may not go to its API unless your BAA expressly lists the API Services. (OpenAI, HIPAA Implementation and Configuration Guide, verified November 15, 2026) Anthropic notes PHI in API use typically appears in prompts and responses, attached files, and file names. (Anthropic, API and data retention - Claude Docs, verified November 15, 2026)
- Lovable: logs alone are not audit evidence. Lovable says its logs help diagnose problems but do not, on their own, prove who made a particular database change. (Logs - Lovable Documentation, verified November 15, 2026)
Patient-facing apps: the FDA question
FDA says the first step in deciding whether software is a medical device is to define its intended use. (How to Determine if Your Product is a Medical Device | FDA, verified November 15, 2026) A device includes something intended for use in diagnosing disease or in its treatment or prevention. (How to Determine if Your Product is a Medical Device | FDA, verified November 15, 2026) Certain decision support software is excluded from the device definition, (Clinical Decision Support Software | FDA, verified November 15, 2026) but FDA's existing digital health policies still apply to software functions that are devices, including ones meant for patients. (Clinical Decision Support Software | FDA, verified November 15, 2026)
Fabrica, from PAHL's own page
Fabrica is a HIPAA-ready environment where physicians and staff build their own apps with AI coding tools, on synthetic patient data. PAHL signs a BAA with your practice and confirms one is in place with each vendor that handles PHI. Automated security checks run on every change, and an expert reviews every release that touches PHI. The process starts with a Week 0 assessment: short interviews covering what you have built, what you want next, and where patient data goes today. A fixed quote follows, before any build work starts.
Inside a Fabrica assessment: what Week 0 is, and is not
Fabrica's page describes the Week 0 assessment as short interviews, not an audit report. They cover three topics. Under each is what to be ready to describe:
- What you have built. For example: the app, the tool you built it in, who uses it, and whether real patients are already in it.
- What you want next. Features you plan to add. Each one may bring a new service that touches PHI.
- Where patient data goes today. Every place PHI (protected health information) is stored, sent or displayed, including the ones that are easy to miss (listed further down).
What comes out of it is a fixed quote, before any build work starts. After that, Fabrica's stated process is: Weeks 1 to 2, an environment created in a cloud account your practice owns, with the agreements in place; Weeks 2 to 3, your existing app moved in (or a first one built) and connected to your EHR; Week 4, release with a staff walkthrough and a handover record. Fabrica describes this as first app live in about 30 days. The release checks below run before that release and before each later one, and an expert reviews every release that touches PHI. For the full timeline, see how long it takes to make a vibe-coded app HIPAA-ready.
How to prepare
- The name of every tool and service the app uses: builder, database, hosting, sign-in, file storage, AI model, email or text messaging, analytics, error tracking.
- For each one, whether you have a signed BAA, and on which plan. The Stack Checker lists the gaps for common stacks.
- Who uses the app (front desk, MAs, clinicians, patients) and what each group should and should not see.
- Whether the app tells patients anything clinical, such as what to do about a symptom or a result.
- Which EHR you use and what the app needs from it.
Fabrica's page asks you not to share patient information on the call. That includes screenshots with real names and a demo logged in as a real patient.
The checks before each release, and the rule behind each
Fabrica's page lists five things checked before each release. The middle column below is our plain-language note on where each one tends to break in a vibe-coded app; the right column is the rule or vendor document behind it.
| Check | Where it tends to break | Why it matters |
|---|---|---|
| No credentials or keys exposed | Database master keys, AI model keys or messaging keys sitting in browser code, in the code repository, or pasted into the builder chat. | A service role key bypasses every row rule in Supabase. (Securing your data | Supabase Docs, verified November 15, 2026) |
| Each user reaches only the records their role permits | A table with no row rules, often one an AI agent added last week. The simple test: sign in as a front-desk user, or as one patient, and try to open another patient's record. | Access control is a Security Rule standard, (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026) and a public-schema table without RLS can be read, edited and deleted by anyone with your project URL. (Performance and Security Advisors | Supabase Docs, verified November 15, 2026) |
| Access to patient records is logged | Only error logs exist. What is needed is a record of who opened which patient's record and when, kept and reviewed. | Audit controls and regular activity review are required. (HHS (eCFR), 45 CFR 164.312 -- Technical safeguards., verified November 15, 2026) (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026) |
| No new outside service receives PHI without an agreement | A new AI summarize button, text reminders, email, error trackers, analytics, log forwarding, and any new package an AI agent pulled in. | Satisfactory assurance is required before a vendor handles PHI. (HHS (eCFR), 45 CFR 164.502 -- Uses and disclosures of protected health information: General rules., verified November 15, 2026) |
| Patient-facing apps: clinical safety review and medical-device assessment | A feature that tells a patient what to do, with no one having asked what happens when the answer is wrong, or what the app's intended use is. | FDA's device question starts from intended use. (How to Determine if Your Product is a Medical Device | FDA, verified November 15, 2026) See clinical safety review for AI-built medical tools. |
Around these, Fabrica runs automated security checks on every change, logs every access to a patient record, uses role-based access and multi-factor sign-in (a second step, such as a code on your phone), keeps PHI encrypted in transit and at rest in the practice's own cloud account, and provides documentation for your Security Risk Analysis, updated yearly.
What this means for your app: where a review looks that you might not
A good review does not start with the database. It starts by following one patient's information through the whole app. In vibe-coded apps, PHI tends to collect in these places:
- The builder chat and screenshots. Real names pasted into a prompt to fix a bug go to the builder's servers. They never show up in your app's database, so a database check misses them.
- Seed and demo data. A test record copied from a real chart, now sitting in every copy of the app.
- The sign-in table. Patient names, emails and phone numbers live there even if the clinical data is elsewhere.
- Uploaded files. Insurance cards, photos, consent PDFs, often in separate storage with its own rules.
- Logs and error trackers. A failed form submission printed to the log, field by field. (Vercel, Runtime Logs, verified November 15, 2026)
- Analytics and session replay. Page addresses and recorded clicks can carry patient details; Vercel's own analytics docs warn that URLs and query parameters may contain sensitive data. (Vercel, Redacting Sensitive Data from Web Analytics Events, verified November 15, 2026)
- AI calls. Prompts, responses, attachments and file names. (Anthropic, API and data retention - Claude Docs, verified November 15, 2026)
- Email and text content. A reminder that names the patient and the visit type can carry PHI to the messaging vendor.
- Preview deployments. A test copy wired to the live database. (How to build and maintain HIPAA-compliant applications on Vercel, verified November 15, 2026)
- Backups and exports. A spreadsheet download on a staff laptop.
The review then asks one question per stop: is there a signed agreement, and does the setting that agreement depends on actually stay on? Whatever it finds decides the next step. If PHI only needs to move to BAA-covered services, the app itself can often stay. If the builder cannot export your code or data, the answer shifts. Keep, refactor or rebuild walks through that decision. The HIPAA checklist for vibe-coded apps is a good self-check before any outside review.
What a review does not do
- It does not certify anything. No authority certifies software as HIPAA compliant. A review produces findings and evidence, not a stamp.
- It does not replace your risk analysis. The risk analysis is your practice's Required document. (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026) A review feeds it. The risk analysis template and HHS's Security Risk Assessment (SRA) Tool, (HHS ONC (HealthIT.gov), Security Risk Assessment Tool - ONC - Office of the National Coordinator for Health Information Technology, verified November 15, 2026) built for small and medium providers, (HHS ONC (HealthIT.gov), Security Risk Assessment Tool - ONC - Office of the National Coordinator for Health Information Technology, verified November 15, 2026) help you write it.
- It does not cover your policies or training. Under Fabrica, your practice remains the covered entity, responsible for its policies, workforce training and risk analysis.
- It does not last forever. A review describes the app on the day it was done. The next AI-generated feature can undo it, which is why the rule expects re-evaluation after changes. (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026)
- It does not decide legal questions. Whether a past exposure needs notification is for your counsel.
Other kinds of review, and when they fit better
Fabrica is one way to get an app reviewed. It is not the only one, and for some practices it is not the right one.
| Option | What it covers well | What it leaves to you | Better choice when |
|---|---|---|---|
| Self-check with vendor tools | Known misconfigurations, such as Supabase's built-in advisors that flag misconfigured RLS. (Performance and Security Advisors | Supabase Docs, verified November 15, 2026) | Anything outside that vendor: AI calls, messaging, logs elsewhere, BAAs. | The app is small, on one or two covered services, and someone on staff reads code. |
| HHS SRA Tool | A guided walk through your practice's security risk assessment. (HHS ONC (HealthIT.gov), Security Risk Assessment Tool - ONC - Office of the National Coordinator for Health Information Technology, verified November 15, 2026) | Testing the app itself. | You need the risk analysis written first. |
| Independent security firm or penetration test | Attempts to break in, with a formal report. | Fixing what it finds; BAAs; ongoing review. | A health system or buyer asked for a third-party report. See what a health-system security review means. |
| A developer you hire | Fixing code and moving data to covered services. | Depends on the engagement; compliance ownership needs to be spelled out. | You want a one-time rebuild and have someone to maintain it. See Fabrica vs. hiring a developer. |
| Fabrica | Assessment, a BAA-covered environment, and checks before every release that touches PHI. | Policies, training, the risk analysis, notification decisions. | You plan to keep building with AI tools and want each release reviewed. |
What sets the scope. For any review: how many outside services touch PHI, whether real patients are already in the app, whether you can export code and data, whether it connects to your EHR, and whether it is patient-facing. A one-time review describes the app on one day; ongoing review repeats with each change. Fabrica gives a fixed quote after the assessment, before build work starts.
How this goes wrong: the review that only checked the database
Hypothetical scenario. Imagine a family physician who built a patient check-in app with a coding agent: a Supabase database with a signed BAA and the HIPAA add-on, (HIPAA Projects | Supabase Docs, verified November 15, 2026) and Vercel hosting on a Pro plan with a signed BAA. (Vercel, Security & Compliance Measures, verified November 15, 2026) Before launch she asks a software-engineer friend to do a HIPAA review. He opens the Supabase Security Advisor and sees no RLS warnings. He searches the browser code and finds no service role key. He says it looks good. For the database, it does.
Three things sat outside what he was asked to look at. First, when a check-in form fails, the code prints the whole submission to the log, and runtime logs capture that output in preview and production alike. (Vercel, Runtime Logs, verified November 15, 2026) Those logs are forwarded to a monitoring service set up during the prototype phase, with no BAA. Second, the preview deployment her agent creates for each change points at the live database, the setup Vercel's own HIPAA guidance advises against. (How to build and maintain HIPAA-compliant applications on Vercel, verified November 15, 2026) Third, a late feature tells patients whether their symptoms mean they should come in today. Nobody asked what that feature's intended use was, which is where FDA's device question starts. (How to Determine if Your Product is a Medical Device | FDA, verified November 15, 2026)
None of this shows up in a database check. A review that starts by following one patient's check-in through every service, and that includes a clinical safety question for patient-facing features, would likely have caught all three before launch. Under the breach rule, an improper disclosure is presumed to be a breach unless a documented risk assessment shows a low probability that the data was compromised. (HHS (eCFR), 45 CFR 164.402 -- Definitions., verified November 15, 2026) Whether the forwarded logs need notification is a question for her counsel.
Keep, refactor, or rebuild?
A narrow review (one database, one tool) can be enough for a small app on covered services with someone technical on staff. If the app sends PHI to several services, is patient-facing, or keeps changing with AI tools, the review that matters is the one that follows patient data end to end and repeats before each release. Fabrica is built around that repeated check; your practice still owns its risk analysis and policies.
A review is what tells you which one your app needs. If the findings are mostly about where PHI goes, the call is usually Keep: the design and code stay, PHI moves to BAA-covered services, and safeguards are added. If sign-in, the data layer or hosting have to be replaced, it is a Refactor. If the builder cannot export code or data in a usable form, the current app becomes the specification for a Rebuild. Fabrica's stated answer for existing apps is: in most cases, yes, they can be kept and moved in. The assessment is where that question starts for your app.
Frequently asked questions
Does passing a HIPAA app review mean my app is officially compliant?
No. No authority certifies software as HIPAA compliant. A review gives you findings and evidence for your own risk analysis, which is a Required part of the Security Rule. (HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards., verified November 15, 2026) Your counsel or privacy officer decides what the findings mean for your practice.
What should I bring to a Fabrica assessment?
A list of every service your app uses, which ones you have BAAs with, who uses the app, whether it is patient-facing, and which EHR you use. Do not bring patient information, real-patient screenshots, or a demo logged in as a real patient.
Does the Fabrica assessment test my code?
The Week 0 assessment is short interviews about what you have built, what you want next and where patient data goes today, followed by a fixed quote. The detailed checks (exposed keys, role-based access, access logging, an agreement before any new service receives PHI, and for patient apps a clinical safety and medical-device assessment) run before release and before every later release that touches PHI.
Will a review find PHI I pasted into the builder chat?
Only if the review asks about it. Builder chats, screenshots and seed data are easy to miss because they never appear in the app's database. Tell the reviewer up front. If it already happened, see what to do if you pasted patient information into ChatGPT.
My app has no patient data. Do I need a review?
Maybe not. Start with does HIPAA apply to the app you built? Check the sign-in table first, though. Email addresses are on HIPAA's list of identifiers that must be removed before data counts as de-identified, (HHS (eCFR), 45 CFR 164.514 -- Other requirements relating to uses and disclosures of protected health information., verified November 15, 2026) so a table of your patients' names and emails may hold PHI even when the app stores nothing clinical. Your privacy officer can confirm.
How long does a HIPAA app review take?
It depends on how many services touch PHI, whether real patients are already in the app, and whether you can export code and data. Fabrica's stated process is a Week 0 assessment and first app live in about 30 days. See a realistic timeline.
Palo Alto Health Labs Fabrica
Keep building. We make it safe.
Want to know what a review would find in your app? Bring your list of services to the call, not your patient data.
Fabrica moves the patient data in your vibe-coded app into an environment your practice owns, built for HIPAA compliance, with a BAA. You keep building in the tool you already use. Start with a 30-minute call about what you have built and where patient data goes today.
See how Fabrica works and book a 30-minute call
Please do not send patient information when you get in touch. The call is a conversation, not an audit or legal advice.
Sources
Every vendor statement on this page comes from the vendor's own terms, documentation or trust pages, or from the regulator, opened and read on the date shown. Vendor terms change; confirm the current version and your own signed agreement before relying on it. This page is general information, not legal advice.
- HHS (eCFR), 45 CFR 164.308 -- Administrative safeguards.. Checked November 15, 2026. Page dated eCFR text current as of 2026-11-12 (Title 45 up to date as of 2026-11-12).
- HHS (eCFR), 45 CFR 164.312 -- Technical safeguards.. Checked November 15, 2026. Page dated eCFR text current as of 2026-11-12 (Title 45 up to date as of 2026-11-12).
- HHS (eCFR), 45 CFR 164.502 -- Uses and disclosures of protected health information: General rules.. Checked November 15, 2026. Page dated eCFR text current as of 2026-11-12 (Title 45 up to date as of 2026-11-12).
- HHS (eCFR), 45 CFR 160.103 -- Definitions.. Checked November 15, 2026. Page dated eCFR text current as of 2026-11-12 (Title 45 up to date as of 2026-11-12).
- Row Level Security | Supabase Docs. Checked November 15, 2026.
- Performance and Security Advisors | Supabase Docs. Checked November 15, 2026.
- Securing your data | Supabase Docs. Checked November 15, 2026.
- Business Associate Agreement (Supabase Legal / Customer Legal Resources). Checked November 15, 2026. Page dated Version 1 — October 23, 2026.
- How to build and maintain HIPAA-compliant applications on Vercel. Checked November 15, 2026. Page dated Published 2025-11-03; last_updated 2026-10-02 (per page metadata).
- Vercel, Runtime Logs. Checked November 15, 2026. Page dated dateModified 2026-08-28 (per page metadata).
- OpenAI, HIPAA Implementation and Configuration Guide. Checked November 15, 2026. Page dated Posted: July 9, 2026.
- Anthropic, API and data retention - Claude Docs. Checked November 15, 2026.
- Logs - Lovable Documentation. Checked November 15, 2026.
- How to Determine if Your Product is a Medical Device | FDA. Checked November 15, 2026. Page dated 2022-09-29.
- Clinical Decision Support Software | FDA. Checked November 15, 2026. Page dated Content current as of 01/29/2026.
- Vercel, Redacting Sensitive Data from Web Analytics Events. Checked November 15, 2026. Page dated dateModified 2026-06-26 (per page metadata).
- HHS ONC (HealthIT.gov), Security Risk Assessment Tool - ONC - Office of the National Coordinator for Health Information Technology. Checked November 15, 2026. Page dated Last Updated: September 18, 2026.
- HIPAA Projects | Supabase Docs. Checked November 15, 2026. Page dated Updated Oct 30, 2026.
- Vercel, Security & Compliance Measures. Checked November 15, 2026. Page dated Last updated September 8, 2026.
- HHS (eCFR), 45 CFR 164.402 -- Definitions.. Checked November 15, 2026. Page dated eCFR text current as of 2026-11-12 (Title 45 up to date as of 2026-11-12).
- HHS (eCFR), 45 CFR 164.514 -- Other requirements relating to uses and disclosures of protected health information.. Checked November 15, 2026. Page dated eCFR text current as of 2026-11-12 (Title 45 up to date as of 2026-11-12).