A prototype demonstrates an idea. Before patient use, you need different evidence: who may access information, where it goes, who is accountable, and what happens when a system fails.
Use this checklist to structure review, not to certify the app. HIPAA applicability depends on roles, relationships, and data flows. HHS does not endorse, certify, or recommend specific cloud products. [1][2]
How to read the labels
Obligation describes a high-level applicable duty, not every specification or exception. Recommendation describes an implementation choice. Scope decision must be resolved before applying the framework.
The currently effective Security Rule has mandatory standards and both required and addressable implementation specifications. Addressable does not mean optional: assess reasonableness and appropriateness, implement when appropriate, or document why not and implement an equivalent alternative if reasonable and appropriate. [3][13]
HHS's August 2026 summary identifies the currently effective rule separately from the NPRM. Stronger express encryption and MFA requirements appear in the proposed-rule fact sheet; this article does not present proposals as effective law. Recheck final-rule status and compliance dates before operational reliance. [3][14]
Reusable project checklist
Copy this section into your review record. For each section assign an owner, evidence location, and open issue. A checked box should mean evidence was reviewed, not merely that a feature exists.
For an alternative evidence-gathering format, see the 15-question evidence self-assessment, a worksheet with no pass/fail score or launch threshold.
Project/version/environment: ______ Review date: ______
Clinical owner: ______ Security owner: ______ Legal/privacy reviewer: ______
1. Scope and permitted information use
- ☐ Scope decision: Identify the operator, customer/practice, covered entities, business associates, subcontractors, and other parties. Not every physician or health app is automatically a covered entity; document the rationale. [1][2]
- ☐ Obligation: Review permitted uses/disclosures and applicable patient rights alongside security and breach duties. Security controls alone do not authorize a use of PHI. [2][3]
- ☐ Recommendation: Define users, intended clinical workflow, data categories, and prohibited uses. Seek separate advice about other applicable privacy and clinical-product obligations.
- ☐ Recommendation: Use entirely invented MOCK/SYNTHETIC fixtures in development. Do not assume removing names from record-derived data satisfies HIPAA de-identification processes. [2]
Owner / evidence / gaps: ______
2. Vendor and service boundaries
- ☐ Recommendation: Diagram builder/code generation, preview/deployment, production hosting, model endpoint, data store/backups, and telemetry/support separately. Include uploads, exports, caches, agent tools, and browser paths.
- ☐ Obligation: Put appropriate BAAs in place before applicable business associates handle ePHI; evaluate the subcontractor chain. An encrypted cloud store can still be a business associate without its decryption key. [2][3]
- ☐ Recommendation: Record each agreement, account, eligible service/feature/model/endpoint, retention setting, required configuration, and responsible party. Mark unresolved paths “PHI blocked.”
- ☐ Recommendation: Do not infer coverage from BYOK, self-hosting, training exclusions, or a BAA alone. Match the actual workflow to eligible scope; vendors distinguish covered and excluded functionality. [2][10][11]
Owner / evidence / gaps: ______
3. Administrative safeguards
- ☐ Obligation: Complete an accurate and thorough risk analysis for ePHI confidentiality, integrity, and availability; manage identified risks. Assign the security official and responsibilities. [3]
- ☐ Obligation: Establish workforce authorization, access management, security training, and incident-handling policies and procedures. Address onboarding, role changes, and offboarding. [3]
- ☐ Obligation: Establish contingency plans covering backups, restoration, and emergency-mode operations; periodically evaluate technical and nontechnical safeguards. [3]
- ☐ Obligation: Keep required Security Rule documentation for six years after creation or the last effective date, whichever is later. This is not a universal six-year retention rule for patient records or every log. [3]
- ☐ Recommendation: Rehearse incident response and restoration. Record findings and owners; do not invent a universal audit schedule.
Owner / evidence / gaps: ______
4. Physical safeguards
- ☐ Obligation: Address facility access, workstation use/security, and device/media controls, including disposal and reuse, as applicable. Cloud hosting does not remove safeguards for clinician workstations. [2][3]
- ☐ Recommendation: Review device management, screen locking, lost-device response, and access to developer machines. Allocate cloud-facility responsibilities explicitly.
Owner / evidence / gaps: ______
5. Technical safeguards and application tests
- ☐ Obligation: Implement appropriate access control, audit controls, integrity protections, authentication, and transmission security. Record applicable specifications and implementation decisions. [3]
- ☐ Recommendation: Use unique accounts, least privilege, and MFA, especially for privileged access. MFA is an implementation recommendation here, not a blanket current-rule mandate; risk findings or contracts can affect required controls. [3][14]
- ☐ Recommendation: Enforce server-side authorization. Test that one user or organization cannot read, alter, export, or delete another's records. RBAC and row-level security can help; neither a toggle nor a successful login proves isolation.
- ☐ Obligation: Evaluate encryption at rest and in transit as addressable specifications under the currently effective rule. Implement when reasonable and appropriate; document contrary determinations and equivalent alternatives if reasonable and appropriate. Addressable is not permission to skip the assessment; contracts may be stricter. [3][13]
- ☐ Recommendation: Prefer encryption with managed key access. Keep secrets outside source code and client bundles; rotate exposed credentials and test recovery.
- ☐ Recommendation: Generate useful audit events without copying clinical content into general logs. Test analytics, replay, traces, URLs, errors, and support exports for leakage; protect resulting logs and assess their classification.
- ☐ Recommendation: Separate production/test identities, storage, models, and secrets. Review preview permissions, caching, uploads, dependencies, and rollback; use MOCK/SYNTHETIC negative tests.
Owner / evidence / gaps: ______
6. Rights, incidents, and release decision
- ☐ Obligation: Support applicable patient rights and business-associate commitments, including access, amendment, and accounting where relevant; plan for appropriate return/destruction at termination. [1][2]
- ☐ Obligation: Identify, respond to, mitigate, and document incidents; assess applicable breach notifications and contractual reporting. Do not assume every incident has one universal reporting deadline. [2][3]
- ☐ Recommendation: Review clinical failure modes, escalation, and human oversight separately. A security checklist does not establish clinical safety.
- ☐ Recommendation: Record launch blockers, unresolved risks, named approvers, and next-review triggers. Keep PHI out of unapproved paths pending responsible review.
Release decision / rationale / approvers: ______
Turn the checklist into decisions
Give each gap an owner and an evidence request. Decide what to keep, refactor, replace, or defer. Revisit the record when a model, integration, vendor term, or clinical workflow changes—even if the interface barely changes.
Bring the checklist and a MOCK/SYNTHETIC walkthrough to the discussion, not a patient export.
See Fabrica and book a 30-minute call
FAQs
Does signing every BAA establish compliance?
No. Appropriate agreements are only part of the privacy, security, and breach framework; the organization retains its applicable obligations. [2][3]
Are MFA and RLS literal current HIPAA requirements?
They are recommended implementations here. The current rule is technology-neutral; HHS separately proposes an express MFA requirement. Do not confuse that proposal with effective law or ignore controls your risk analysis or contracts require. [3][14]
Sources
All accessed November 7, 2026 (PT). Reference numbers are shared across these guides.
- HHS: Covered Entities and Business Associates.
- HHS: Guidance on HIPAA & Cloud Computing.
- HHS: Summary of the HIPAA Security Rule.
- Cursor: HIPAA Business Associate Agreements.
- OpenAI: HIPAA eligible products and functionality.
- HHS: Encryption implementation specification.
- HHS: Security Rule NPRM fact sheet.
We make no guarantee of compliance or outcome.
See Fabrica and book a 30-minute call
A free 30-minute call about your app or your practice's technology. You leave with a recommended next step. It is not an audit, a certification or legal advice.