How to Scope a Clinical Imaging Labeling Project

Most imaging labeling projects that go sideways don't fail at the annotation step. They fail earlier, when nobody wrote down what the label means, who is qualified to apply it, or how the labeled data will be used as evidence later. This guide walks AI teams through scoping a clinical imaging labeling project so the output holds up in model development, in publication, and, where relevant, in an FDA submission.

Format
Guide
Updated
Oct 28, 2026

Palo Alto Health Labs is expanding into clinical data labeling across data types and specialties, with imaging as a strength. We plan to scope imaging projects with board-certified radiologists and other specialists, starting from the questions below.

Step 1: Start from the intended use, not the dataset

Write one sentence: what will the model do, for whom, in what clinical setting? Everything else follows from it.

If the labels might support a 510(k) for a computer-assisted detection (CADe) device, read FDA's two CADe guidances early. They describe what FDA expects about the reference standard, reader qualifications, and study design for radiology CADe devices [1, 2]. This is not legal or regulatory advice; consult qualified counsel.

Step 2: Define the label schema in writing

A label schema is the contract between your team and your annotators. It should include:

The CLAIM checklist (Checklist for Artificial Intelligence in Medical Imaging) asks authors to report how ground truth was defined, who the annotators were and what their qualifications were, the annotation instructions and tools, and how annotator variability was measured [3, 4]. Scoping against CLAIM up front means the documentation you'll need later is produced as you go.

Step 3: Choose the data format and annotation standard

Keep the images in DICOM and store annotations in a standard, interoperable form wherever possible. DICOM defines object types for annotation results, including Segmentation objects and Structured Reports for measurements and findings [5, 6]. Proprietary JSON exports from a labeling tool are fine for working copies, but plan a conversion path so labels stay tied to the correct Study, Series and SOP Instance UIDs.

Checklist:

Step 4: Decide who labels, and how many readers

Match annotator qualifications to the clinical judgment the label requires.

Illustrative example. The table shows the kinds of choices a scope document records. It is not a recommendation or evidence about how many readers a project needs.

Label type Who might label Review approach to decide
Presence/absence of a finding Radiologist or relevant subspecialist Whether and how a second reader checks disagreements
Subtle or high-stakes findings Subspecialty radiologists Independent readers and a pre-specified adjudication rule
Segmentation for training Trained annotators Specialist review and correction of masks
Reference standard for a test set Qualified specialists, blinded Independent reads, a pre-specified adjudication rule, and other reference sources where available
Report text or multimodal labels Specialist matching the clinical domain Who adjudicates disagreements

Your statistician and, for a CADe device, FDA's CADe guidances should drive the final reader design [1, 2].

Step 5: Plan quality measurement before labeling starts

Step 6: Write the scope document

A complete scope document answers: intended use; modality, body part and protocol; case mix and enrichment; label schema and examples; annotator qualifications; readers per case and adjudication rule; blinding; agreement metrics and thresholds; data formats and delivery; de-identification and data handling; timeline and checkpoints. If any line is blank, the project isn't scoped yet.

Common pitfalls

  1. Labeling before defining. Annotators fill gaps in the schema with personal judgment, and agreement collapses.
  2. Mixing training labels and reference-standard labels. Test-set labels need independent, blinded readers and a pre-specified adjudication rule.
  3. Unblinded readers. Access to the radiology report or the model output can bias labels.
  4. Spectrum mismatch. An enriched or single-site case mix may not reflect the intended-use population.
  5. Format lock-in. Labels that live only inside one vendor's tool, without UID links, are hard to audit or reuse.
  6. No documentation trail. Without dated schema versions and adjudication logs, you can't answer CLAIM items or regulator questions later.

Where PAHL fits

PAHL is launching clinical data labeling services across data types and specialties, with imaging as a strength. We plan to scope imaging projects with board-certified radiologists, and we bring epidemiology and clinical research study design to the questions above. If you're planning an imaging labeling project, get in touch or book a consult at paloaltohealthlabs.com.

This is not legal or regulatory advice; consult qualified counsel.

Sources

  1. FDA. Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data in Premarket Notification (510(k)) Submissions. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/clinical-performance-assessment-considerations-computer-assisted-detection-devices-applied-radiology (final guidance, September 2022; docket FDA-2009-D-0503)
  2. FDA. Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device Data – Premarket Notification [510(k)] Submissions. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/computer-assisted-detection-devices-applied-radiology-images-and-radiology-device-data-premarket (final guidance, September 2022; docket FDA-2009-D-0503)
  3. Mongan J, Moy L, Kahn CE Jr. Checklist for Artificial Intelligence in Medical Imaging (CLAIM): A Guide for Authors and Reviewers. Radiol Artif Intell 2020;2(2):e200029. doi:10.1148/ryai.2020200029
  4. Tejani AS, Klontzas ME, Gatti AA, Mongan JT, Moy L, Park SH, Kahn CE Jr, et al. Checklist for Artificial Intelligence in Medical Imaging (CLAIM): 2024 Update. Radiol Artif Intell 2024;6(4):e240300. doi:10.1148/ryai.240300 https://doi.org/10.1148/ryai.240300 (metadata confirmed via Crossref)
  5. DICOM Standard (current edition). https://www.dicomstandard.org/current
  6. DICOM PS3.3, Information Object Definitions (Segmentation and Structured Report IODs). https://dicom.nema.org/medical/dicom/current/output/html/part03.html