Prepared with the Palo Alto Health Labs Co-Scientist. Not peer-reviewed.
Diabetes is common: the World Health Organization reports that in 2022, 14% of adults aged 18 years and older were living with diabetes (WHO fact sheet). Software already shapes how the disease is found and treated, and artificial intelligence (AI) tools are increasingly being evaluated. This rapid review asks a simple question: for AI and digital-health tools in type 2 diabetes, how strong is the 2024–2026 evidence that they work outside the lab?
Key findings
- Eye screening AI is the most mature use. Across ten studies of diabetic retinopathy (DR) screening, pooled across mixed thresholds and units, AI caught about 9 in 10 cases (sensitivity 90.3%, 95% confidence interval [CI] 82.4–94.9%) and correctly cleared about 9 in 10 people without disease (specificity 92.3%, 80.0–97.3%). The six studies using a referable-DR threshold gave 92.2% (82.3–96.8%) and 94.7% (73.9–99.1%). Performance in a new setting could differ substantially, so local validation before and during deployment matters.
- Automated insulin dosing now has randomised trials. One trial, with 319 participants, found more time in the target glucose range with automated insulin delivery (AID) than usual insulin plus CGM. The trials are few and had no formal risk-of-bias assessment.
- Risk-prediction models discriminate moderately. Most were checked only on past data, not tested prospectively.
- No digital-coaching study qualified. This is an evidence gap, not proof that coaching fails.
- Caveats. Results varied widely between studies (specificity I² 98.9%). The 95% prediction intervals ran from 48.4% to 98.9% for sensitivity and from 16.0% to 99.9% for specificity. Only 10 of 34 included DR studies could be pooled. No formal risk-of-bias assessment was done. Three of the 10 pooled studies were developer-affiliated (excluding them: 86.8% / 93.5%). Six studies were excluded under a post hoc date rule. The pooled estimates are a descriptive summary, not the accuracy of any single test or product.

Evidence maturity at a glance
The four use cases sit at very different stages. DR screening carries most of the evidence. The other areas are at earlier or uneven stages.
| Use case | Included studies (k) | Designs | Headline result | Confidence |
|---|---|---|---|---|
| DR screening | 34 included; 10 pooled | 18 prospective accuracy, 14 real-world, 2 retrospective | Sensitivity 90.3% (82.4–94.9), specificity 92.3% (80.0–97.3) | Low to moderate for the pooled average; low for any single setting |
| Insulin dosing / AID | 8 | 6 randomised, 2 single-arm | AID vs usual insulin plus CGM: time in range (TIR) +14 percentage points (95% CI 11 to 17), n = 319 (single RCT) | Moderate; few trials, no RoB 2 |
| Risk prediction | 12 | Mostly retrospective external validation | Prediabetes progression AUC 0.74 (0.71–0.78), n = 3,081 (single external validation) | Low to moderate |
| Digital coaching | 0 | None met criteria | None | Evidence gap |
RCT is a randomised controlled trial; AUC is the area under the curve, a measure of how well a model separates people who will and will not develop a condition. Confidence is an informal reviewer judgement, not a formal GRADE rating. It considers study design (randomised or prospective rated higher than retrospective), number of studies, consistency and precision of results, and directness to routine care. No formal risk-of-bias assessment was done for any area (including RoB 2 for trials), which caps every rating at moderate.

| Use case | Studies (k) | Designs | Headline result | Confidence |
|---|---|---|---|---|
| DR screening | 34 included; 10 pooled | 18 prospective accuracy, 14 real-world, 2 retrospective | Sens 90.3% (82.4–94.9) Spec 92.3% (80.0–97.3) | Low to moderate (pooled average); low for any single setting |
| Insulin dosing / AID | 8 | 6 randomised, 2 single-arm | TIR +14 pp (95% CI 11 to 17) AID RCT, n = 319 (single RCT) | Moderate; few trials, no RoB 2 |
| Risk prediction | 12 | Mostly retrospective external validation | Prediabetes progression AUC 0.74 (0.71–0.78), n = 3,081 (single external validation) | Low to moderate |
| Digital coaching | 0 | None met criteria | None | Evidence gap |
Eye screening: AI is accurate on average, but varies by setting
On average, DR screening AI catches about 9 in 10 cases and clears about 9 in 10 people without disease. Each clinic should still check its own performance, because results differed a lot between settings.
Ten studies reported enough data to build a 2×2 table of true and false results. They were pooled across mixed thresholds and units with the Reitsma bivariate model. Three key analyses are below; all twelve are in Appendix A.
| Analysis | k | Sensitivity (95% CI) | Specificity (95% CI) |
|---|---|---|---|
| Primary, bivariate | 10 | 90.3% (82.4–94.9) | 92.3% (80.0–97.3) |
| Excluding developer-affiliated studies (Skevas, Abreu-Gonzalez, Šín) | 7 | 86.8% (74.6–93.7) | 93.5% (74.3–98.6) |
| Strictly reported counts only (unstable fit) | 5 | 92.3% (76.2–97.8) | 96.2% (80.6–99.4) |
Point estimates changed little across the sensitivity analyses: excluding the three developer-affiliated studies gave 86.8% (74.6–93.7) and 93.5% (74.3–98.6), and every other variant's point estimate stayed within the primary confidence intervals. This does not offset the wide prediction intervals. The 95% prediction intervals, which show the range a new setting might see, were 48.4–98.9% for sensitivity and 16.0–99.9% for specificity. Between-study variation (I²) was 78.0% for sensitivity and 98.9% for specificity. The summary receiver operating characteristic (SROC) curve gave an AUC of 0.95, with a between-study correlation of 0.10. Deeks' test for small-study effects gave p = 0.82, but it has low power at k = 10.


Only 10 of 34 included DR studies had extractable 2×2 data. The other 24 are listed in Appendix B, 4 of them pending full-text extraction. Thresholds (referable DR, more-than-mild DR, any DR) and units were mixed, and 3 studies had back-calculated counts (see Limitations).
Included studies:
- Sam 2026, 10.3389/fdgth.2026.1938702
- Abreu-Gonzalez 2025, 10.1136/bmjophth-2024-002109
- Bauer 2025, 10.1055/a-2620-1956
- Grzybowski 2025, 10.1007/s40123-024-01049-z
- Berrada 2026, 10.1038/s41598-026-37292-6
- Antaki 2024, 10.2196/59867
- Skevas 2024, 10.1186/s12886-024-03306-y
- Krogh 2026, 10.1080/02813432.2026.2683982
- Altobelli 2026, 10.1038/s41598-026-58158-x
- Šín 2025, 10.2147/OPTH.S511233
Insulin dosing: randomised trials now support automated dosing
Randomised trials now support AID and algorithmic insulin dosing, but there are few of them. Eight studies were included, six of them randomised. They were synthesised narratively, and each number was checked against its abstract:
- AID vs usual insulin plus CGM, RCT (n = 319). Time in range (TIR) mean difference +14 percentage points (95% CI 11 to 17). 10.1056/NEJMoa2415948
- Closed loop in people already on an insulin pump, randomised crossover (n = 17). TIR 76.0% during closed loop. 10.2337/dc24-0623
- AID, nonrandomised single-arm trial (n = 305). 10.1001/jamanetworkopen.2024.59348
- AI insulin titration (iNCDSS) vs physicians, RCT (n = 149). Target-range time 76.4% vs 73.6%, meeting the noninferiority criterion. 10.1001/jamanetworkopen.2025.8910
- Learning-based meal-bolus support (AP-A) vs physicians, RCT (n = 119). TIR was noninferior (72.4% vs 71.2%). 10.1210/clinem/dgae143
- Algorithmic CGM-based titration, randomised (n = 30). TIR 54.1% → 75.3% vs 50.2% → 55.3%. 10.1177/15209156261420193
The trials are few and vary in design, comparator and size. They were synthesised without formal risk-of-bias assessment.
Risk prediction: moderate accuracy, unproven benefit
Risk models separate higher-risk from lower-risk people moderately well, but none has yet shown that it improves care. Twelve studies were included, synthesised narratively. Most validation used past data. Examples include an AI model reading the electrocardiogram (AI-ECG) to predict new type 2 diabetes (T2D):
- AI-ECG for incident T2D. C-index 0.688 in UK Biobank (n = 65,606) and 0.625 in ELSA-Brasil (n = 13,739). 10.1093/ehjdh/ztag118
- Prediabetes progression model, external validation in the Diabetes Prevention Program (n = 3,081). AUC 0.74 (0.71–0.78). 10.3389/fendo.2026.1746570
- Complications after diagnosis. AUC 0.77–0.85 across complications. 10.1038/s41467-026-76673-3
- Two-stage screening model. AUROC 0.82 in UK Biobank. 10.1136/bmjopen-2025-103171
- Cardiovascular events in older adults with T2D (Medicare claims). Calibration intercept ≈0 and slope ≈1. 10.1016/j.jclinepi.2025.112001
- Other models. AUROC 0.803 (10.1080/17446651.2024.2400706); AUC 0.762 for prevalent T2D detection in external validation (10.1016/j.eclinm.2024.102445).
Discrimination alone does not show that a model improves care.
Digital coaching: no qualifying evidence
No 2024–2026 study of AI-driven digital coaching in type 2 diabetes met the review's criteria (0 included). This reflects the review's eligibility rules and a non-systematic search, not proof that coaching tools do not work. Claims about these tools should be treated cautiously.
Where the evidence sits
The evidence is concentrated in two use cases. The review screened 389 unique records and excluded 320 (6 of them under Amendment 3). Another 15 were include-uncertain and not used. That left 54 included studies (DR 34, risk 12, dosing/AID 8, coaching 0).
- DR screening: 34 (18 prospective accuracy, 14 real-world, 2 retrospective). 10 had extractable 2×2 data; 24 did not (4 pending).
- Risk prediction: 12.
- Dosing/AID: 8, of which 6 were randomised.
- Digital coaching: 0.

What this means for clinics and patients
- Clinics: DR screening AI has the most mature evidence. Average accuracy is high, but the wide prediction intervals mean performance must be checked locally before and after deployment.
- Clinics: AID and algorithmic dosing have randomised support, but from few trials without formal risk-of-bias assessment.
- Clinics: treat risk-prediction models as research or decision-support tools until prospective benefit is shown.
- Patients: an AI eye screen checks whether further eye examination is needed; it does not diagnose all eye disease or treat retinopathy. Under the FDA labelling of the first cleared device (source g), a positive result leads to referral to an eye-care professional, a result that cannot be read means retesting or referral, and a negative result means screening again later. ADA Standards of Care 2026 (Rec 12.6; source f) consider FDA-approved AI screening appropriate when programs provide timely referral. Individual care decisions rest with a clinician.
- Everyone: coaching tools currently lack qualifying evidence. The pooled estimates are not device-specific and should not be read as the performance of any single product.
Limitations
- Rapid, non-systematic review.
- A single reviewer screened and extracted, and no formal risk-of-bias assessment (QUADAS-2, PROBAST or RoB 2) was performed.
- Trial registries were not part of the search, so unpublished or registry-only results are missed.
- Designs ranged from retrospective to prospective real-world screening. Reference standards ranged from a single grader to adjudicated panels.
- Selection. Only 10 of 34 DR studies could be pooled, which may introduce selection bias.
- Pending extraction. Vidal-Alaball 2026, Duggal 2025, Joseph 2025 and Gunasekeran 2024 were not extracted in time and are not in the pool.
- Back-calculated counts.
- In 3 of the 10 DR studies (Antaki, Skevas, Altobelli), counts were back-calculated. Altobelli's counts (24/41/9/89, n = 163) are the only integer solution matching all reported metrics; an earlier draft used 25/43/9/90 in error. Skevas's specificity is not exactly reproduced (161/201 fits better than 163/204); using 27/40/0/161 changed nothing at one decimal.
- Count source (source_type in dr_2x2_v2.5.csv): reported in 5 (Sam, Abreu-Gonzalez, Bauer, Grzybowski, Krogh, whose counts are in its Table 2); derived arithmetically from stated totals in 2 (Berrada, Šín); back-calculated in 3.
- Restricted to the 5 studies with strictly reported counts, sensitivity was 92.3% (76.2–97.8%) and specificity 96.2% (80.6–99.4%); with k = 5 this fit is unstable.
- Restricted to the 7 studies with reported or directly derived counts, sensitivity was 91.5% (82.1–96.2%) and specificity 96.0% (87.0–98.9%).
- Grzybowski 2025: the abstract gives IDx-DR PPV 48.1%, but Table 5 (used here) gives 141/332 = 42.5%.
- Thresholds.
- Pooling across thresholds (referable DR, more-than-mild DR, any DR) mixes different target conditions. The referable-DR-only estimate is the more interpretable figure.
- Altobelli 2026's threshold is uncertain: the reference standard was graded as DR yes/no.
- Units. Krogh 2026 reports counts per image (336 images from 183 patients), so its observations are clustered and its confidence intervals too narrow. Šín 2025 describes 368/1,154 as both patients and eyes; counts were treated as patient-level. The patient-level-only analysis gave similar results.
- Developer involvement and conflicts of interest.
- Under the criterion in Methods, 3 of the 10 DR studies are developer-affiliated: Skevas 2024, Abreu-Gonzalez 2025 (RetinAI-employed co-authors; LuxIA co-developed by RetinAI; also industry-funded) and Šín 2025 (authors affiliated with Aireen).
- Excluding all three, pooled sensitivity was 86.8% (95% CI 74.6–93.7%) and specificity 93.5% (74.3–98.6%). Excluding only Skevas and Abreu-Gonzalez gave 87.8% / 93.1%.
- Post hoc date rule. Amendment 3 was set after screening and removed six studies (Methods).
- Interpretation. The pooled estimates are not device-specific and should not be read as the performance of any single product.
Methods
This is a rapid, non-systematic review. It followed a written protocol with three dated amendments: one narrowing the scope before data extraction, and a post hoc eligibility-date rule (Amendment 3) set after screening. A single reviewer screened and extracted, with no duplicate screening.
Searches.
- Databases. PubMed (E-utilities) and Europe PMC (REST API; MEDLINE records) were searched on 29 October 2026 for records published from 1 January 2024 to 29 October 2026.
- PubMed hits by query: DR 128, risk prediction 121, dosing/AID 111, digital coaching 16, plus a supplementary coaching query with 30.
- Europe PMC hits by query: 114, 104, 93 and 15. Europe PMC added no unique records beyond PubMed.
- Crossref. Every included record's title and DOI were checked against Crossref.
- ClinicalTrials.gov was not searched as part of this review. One exploratory registry query was run after drafting (29 October 2026, 10:03 PT; it returned 3 DR, 11 risk and 17 dosing records). Those records were not screened, and none were used.
- Online-first date rule (Amendment 3, post hoc). Eligibility is by online-first publication date, 1 January 2024 to 29 October 2026. This rule was set after screening, not in the original protocol. Online-first dates for all previously included studies were checked against Crossref, PubMed and PMC (online_dates_check.csv). Six studies were excluded under it: Reznik 2024 and Levy 2024 (dosing), and Chia 2024, Gognieva 2024 (PMC publication date 28 Nov 2023), Salongcay 2024 and Wroblewski 2025 (DR).
- Studies are labelled by journal issue year; Grzybowski 2025 was online in 2024.
Eligibility.
- Population and tools: AI or digital-health tools in adults with diabetes, predominantly type 2.
- Deviation from protocol: several DR studies enrolled mixed type 1 and type 2 populations.
- Designs: external validation, prospective designs or randomisation.
DR synthesis.
- Data extraction: 2×2 tables came from full texts or abstracts, and the source location of every number is recorded.
- Back-calculation: when counts were not reported, they were back-calculated from the reported sensitivity, specificity, n and prevalence, or from PPV/NPV, and flagged.
- One algorithm per study: the first listed. Alternatives were tested in a sensitivity analysis.
- Coverage: of 34 included DR studies, 10 had extractable 2×2 data and were pooled. The other 24 are listed in Appendix B with a reason for each. Šín 2025 was added in this version after its counts were verified from the full text (N = 1,154; 368 with DR; sensitivity 92.1%, specificity 90.7%, PPV 82.3% gives TP 339, FP 73, FN 29, TN 713; FN matches the paper's table).
- Developer affiliation (one criterion, applied to every pooled study): a study is developer-affiliated when its affiliations, disclosures or methods state that at least one author is employed by, or was part of the team that developed, the evaluated algorithm. Industry funding is recorded separately. Statements are quoted in dr_disclosures_v2.3.csv.
- Primary model: the Reitsma bivariate model (REML), with bivariate 95% prediction intervals using t(k−2).
- Check: univariate logit random-effects models (REML with the Hartung–Knapp–Sidik–Jonkman adjustment).
- Small-study effects: Deeks' funnel-plot test.
Software.
- Analyses: R 4.5.3 with mada 0.5.12 and metafor 5.0-1. R ran from a conda-forge environment (run log and sessionInfo() in dr_pool_results_v2.5.txt and dr_strict_reported_v2.4.txt). The environment was a temporary one in /tmp on a shared machine; its package list is pinned in env/.
- Figures: Python 3.13.5 with matplotlib 3.11.2 and SciPy 1.18.1, from the R-fitted estimates.
Narrative synthesis. Risk-prediction and dosing/AID studies were synthesised narratively. Each number in the dosing/AID and risk-prediction sections was checked against the study's PubMed abstract.
Appendix
A. All DR sensitivity analyses.
| Analysis | k | Sensitivity (95% CI) | Specificity (95% CI) |
|---|---|---|---|
| Primary, bivariate | 10 | 90.3% (82.4–94.9) | 92.3% (80.0–97.3) |
| Referable-DR threshold only | 6 | 92.2% (82.3–96.8) | 94.7% (73.9–99.1) |
| Referable DR + Altobelli (threshold uncertain) | 7 | 90.1% (78.6–95.8) | 92.8% (71.2–98.5) |
| Excluding developer-affiliated studies (Skevas, Abreu-Gonzalez, Šín) | 7 | 86.8% (74.6–93.7) | 93.5% (74.3–98.6) |
| Excluding Skevas and Abreu-Gonzalez only | 8 | 87.8% (78.3–93.4) | 93.1% (77.2–98.2) |
| Skevas alternative counts (27/40/0/161) | 10 | 90.3% (82.4–94.9) | 92.3% (80.0–97.3) |
| Patient-level only | 9 | 91.6% (84.2–95.7) | 92.6% (78.5–97.7) |
| Reported or directly derived counts only | 7 | 91.5% (82.1–96.2) | 96.0% (87.0–98.9) |
| Strictly reported counts only (unstable fit) | 5 | 92.3% (76.2–97.8) | 96.2% (80.6–99.4) |
| Excluding Altobelli | 9 | 91.7% (84.5–95.7) | 93.6% (82.2–97.9) |
| Alternative algorithm per study | 10 | 87.4% (80.2–92.2) | 93.6% (84.0–97.6) |
| Univariate check (HKSJ) | 10 | 91.2% (81.7–96.0) | 92.5% (76.6–97.9) |
B. Unextracted DR studies (24 of 34).
| Study | PMID | Reason not pooled |
|---|---|---|
| Vidal-Alaball 2026 | 41883753 | Pending: eye-level (1,652 eyes), sens 86.8% / spec 95.6%; DR prevalence not reported, so 2×2 not recoverable |
| Duggal 2025 | 40925861 | Pending: eye-level; sens 68.4% / spec 96.0% / PPV 86.7% reported; number of diseased eyes not verified |
| Joseph 2025 | 40846450 | Pending: full text not retrieved |
| Gunasekeran 2024 | 42932771 | Pending: full text not retrieved |
| Kubin 2024 | 38738798 | 21 algorithms compared; one-per-study choice and counts not extracted |
| Poschkamp 2026 | 40932047 | Locally customised thresholds; full text on hand; 2×2 not extracted or verified in the time available |
| Hunfeld 2026 | 41611862 | Mixed population (ages 8–92, includes T1D); full text on hand; 2×2 not extracted or verified in the time available |
| Daley 2025 | 40491217 | Full text on hand; 2×2 not extracted or verified in the time available |
| Brant 2025 | 40105843 | Full text on hand; 2×2 not extracted or verified in the time available |
| Yao 2024 | 39676804 | Full text on hand; 2×2 not extracted or verified in the time available |
| Vassallo 2026 | 42938261 | Not extracted in the time available (abstract only on hand) |
| Irlik 2026 | 42373388 | Not extracted in the time available (abstract only on hand) |
| Kelkar 2026 | 42339716 | Not extracted in the time available (abstract only on hand); disease-enriched, multi-disease |
| Chauhan 2026 | 42330215 | Not extracted in the time available (abstract only on hand); multiple algorithms |
| Krzywicki 2026 | 42082068 | Not extracted in the time available (abstract only on hand) |
| Lin 2026 | 41818422 | Not extracted in the time available (abstract only on hand) |
| Ravindran 2026 | 41797256 | Not extracted in the time available (abstract only on hand) |
| Costa 2026 | 41637371 | Not extracted in the time available (abstract only on hand) |
| Parravano 2026 | 41248228 | Not extracted in the time available (abstract only on hand) |
| Huhtinen 2025 | 40824290 | Not extracted in the time available (abstract only on hand) |
| Mbaye 2025 | 39437373 | Not extracted in the time available (abstract only on hand) |
| Taylor 2025 | 39134384 | Not extracted in the time available (abstract only on hand); disease-enriched sample |
| Piatti 2025 | 39109554 | Not extracted in the time available (abstract only on hand) |
| Burlina 2024 | 38995312 | Not extracted in the time available (abstract only on hand) |
C. Figure 1 sources.
- (a) American Diabetes Association. 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2026. Diagnostic criteria (Table 2.1) and the ADA risk test. 10.2337/dc26-S002
- (b) American Diabetes Association. 7. Diabetes Technology: Standards of Care in Diabetes—2026. Recommendation 7.24 (insulin dose calculators/decision support) and AID as the preferred insulin delivery method. 10.2337/dc26-S007
- (c) FDA De Novo DEN180001, diabetic retinopathy detection device, decision 2018-04-11. accessdata.fda.gov
- (d) FDA De Novo DEN170088, integrated continuous glucose monitoring system, decision 2018-03-27. accessdata.fda.gov
- (e) FDA De Novo DEN190034, interoperable automated glycemic controller, decision 2019-12-13. accessdata.fda.gov
- (R) This review: DR pooled estimate (k = 10), AID RCT (n = 319), risk prediction (n = 3,081), coaching (0 qualifying studies), as cited in the sections above. Foot-ulcer/neuropathy imaging placement is a reviewer judgement and is not sourced.
- (f) American Diabetes Association. 12. Retinopathy, Neuropathy, and Foot Care: Standards of Care in Diabetes—2026. Recommendation 12.6. 10.2337/dc26-S012
- (g) FDA De Novo DEN180001 decision summary. DEN180001.pdf
- ADA placements (a, b, f) were checked against the PMC full text on 29 October 2026.
D. Figure files.
- Figure 1: figures/fig1_landscape_v3_6 (.png, .svg); mobile variant (stacked) figures/fig1_landscape_v3_6_mobile_part1–part3 + fig1_landscape_v3_6_mobile_part4_legend (.png, .svg)
- Figure 2: figures/fig2_evidence_maturity_v3_6 (.png, .svg); data table figures/fig2_evidence_maturity_v3_6_table.md
- Figure 3: figures/fig3_dr_forest_v3_6 (.png, .svg); mobile variant (stacked) figures/fig3_dr_forest_v3_6_mobile_sens, _mobile_spec, _mobile_legend (.png, .svg)
- Figure 4: figures/fig4_dr_sroc_v3_6 (.png, .svg); mobile variant figures/fig4_dr_sroc_v3_6_mobile (.png, .svg)
- Figure 5: figures/fig5_evidence_map_v3_6 (.png, .svg); mobile variant (stacked) figures/fig5_evidence_map_v3_6_mobile_part1, _part2, _part3_legend (.png, .svg)
Corrections
None yet.
Found an error? Email hello@paloaltohealthlabs.com.
More from the Palo Alto Health Labs Co-Scientist · All posts
Have your own questions? Sign up for the Beta
Tell us the health AI or digital health question you would want the Co-Scientist to review, and join the beta list.
Scope it in 30 minutes
Book a scoping call and we'll name the smallest engagement that moves you forward. Most teams start with the fixed-scope Initial Audit.
Book a 30-min scoping callPrefer to write? Send a short note.