Palo Alto Health Labs Co-Scientist · 28 October 2026
Disclosure. This is a rapid, non-systematic review. Searching, screening, extraction, analysis and drafting were done and checked by an AI agent (Palo Alto Health Labs Co-Scientist). The work has not been validated by a human reviewer and has not been externally peer reviewed. Numbers come mostly from abstracts, using open-access full text where it was available. Treat the findings as hypothesis-generating, not as clinical guidance.
Abstract
Background. Seizure-detection devices now cover the wrist, the ear, the scalp surface, under the scalp, the heart, muscle, the bed, cameras and phones. Few syntheses compare these modalities side by side, and fewer separate convulsive seizures from focal ones.
Methods. PubMed and OpenAlex were searched on 28 October 2026 (Europe PMC was unavailable and Embase was not searched) for 2024–2026 studies reporting event-level sensitivity and/or false-alarm rate (FAR) against a video-EEG, EEG, or expert-video reference. Sensitivity (logit) and FAR per 24 h (log) were pooled with REML random effects, the Hartung–Knapp–Sidik–Jonkman (HKSJ) adjustment, and prediction intervals (PIs), wherever a modality had k≥3 studies. Studies were reported descriptively otherwise. One arm per study was used.
Results. Of 1,174 records, 42 were included: 33 studies from 2024–2026 and 9 earlier landmark or context reports.
- Wrist/arm devices, convulsive and tonic seizures: pooled sensitivity 95.2% (95% CI 86.4–98.4; 95% PI 82.2–98.9; τ² 0.08; I² (fixed-effect Q) 0%; k=6). The estimate depends on the model: four of six studies detected every seizure, and a binomial-normal GLMM, which needs no continuity correction, gives 98.4% (95% CI 80.8–99.9; 95% PI 47.2–100). FAR 0.108/24 h (95% CI 0.051–0.226; 95% PI 0.018–0.663; τ² 0.25; I² (fixed-effect Q) 79%; k=5), mostly from in-hospital recordings. Sensitivity is counted per seizure, and seizures cluster within patients, so these intervals overstate precision.
- ECG/HRV, all seizures (descriptive only): sensitivity 81.3% (95% CI 56.2–93.7; 95% PI 13.1–99.2; k=4). ECG ± ACC, convulsive 91.9% (95% CI 39.9–99.5; k=3); focal 71.6% (39.8–90.6; k=3).
- Wearable/behind-the-ear EEG (descriptive only): sensitivity 87.2% (95% CI 14.5–99.6; k=3).
Subscalp EEG, sEMG, bed, video/radar, audio, smartphone and intracranial/RNS evidence was too sparse or too heterogeneous to pool.
Conclusions. Wrist-motion devices reach ~95% or higher for convulsive seizures in small, mostly developer-run studies; other modalities have too few or too heterogeneous studies to say. Wrist FAR is about 0.11/24 h, mostly in-hospital (roughly one false alarm every 9 days). No study compared modalities head-to-head. 28 of 33 studies evaluated the authors' own algorithm or involved the device maker. Focal-seizure detection remains the open problem in every modality. Pooled focal sensitivity is about 70% for ECG, and 73% for an algorithm-only behind-the-ear EEG system in the largest study.
1. Introduction
Missed seizures matter. Convulsive seizures carry the main risk of sudden unexpected death in epilepsy (SUDEP), and seizure diaries undercount events: in one 2025 subscalp-EEG cohort, 52% of seizures went unreported [26]. A 2026 systematic review of wearable devices pooled a TCS sensitivity of 89.9% and a FAR of 1.43/24 h, and a focal sensitivity of 73.5% [42]. That review covered body-worn devices only. The present review extends the scope to every modality that can detect a seizure. It also separates convulsive and tonic seizures from focal seizures, and uses small-k-appropriate random-effects methods (HKSJ with prediction intervals).
2. Methods
Design. Rapid review following PRISMA 2020 reporting items where feasible. There was no protocol registration and a single (AI-agent) screener.
Searches (28 October 2026).
-
PubMed (publication date 2024–2026). Nine modality queries combined
seizure*[tiab]with these terms:- behind-the-ear / ear-EEG / around-the-ear / cEEGrid / "sensor dot" / "wearable EEG"
- subscalp / subcutaneous EEG / sqEEG / "24/7 EEG" / ultra-long-term / Epiminder / Minder
- responsive neurostimulation / RNS / intracranial EEG with detection and sensitivity / false / forecast
- ECG / electrocardiogra* / heart rate variability / ictal tachycardia
- surface electromyograph* / sEMG / EMG
- bed / mattress / nocturnal monitor* / NightWatch
- video / camera / radar / Nelli / computer vision, with automat*
- audio / acoustic / sound / microphone
- smartphone / multimodal / smartwatch / wearable*, with sensitivity or "false alarm*"
Targeted follow-up queries covered UNEEG/subscalp and RNS, plus landmark studies from 2022 onward. Full query strings are given in the supplementary search log.
-
OpenAlex (publication date ≥2024-01-01). Twelve free-text queries, e.g., "seizure detection ear EEG", "… subscalp EEG", "… electromyography", "… mattress", "… radar", "… audio", "… smartphone", "responsive neurostimulation seizure detection". The top 100 results by relevance were taken for each.
- Europe PMC and Semantic Scholar were unavailable at the time of searching and were not searched; Embase was not searched.
Eligibility.
- Included: human studies, 2024–2026, testing an automated (or algorithm-plus-review) detector on a named sensing modality against a video-EEG, EEG, or expert-video reference, and reporting event-level sensitivity and/or FAR.
- Excluded: algorithms tested only on public EEG benchmark datasets, animal studies, reviews (kept as context only), and hospital full-montage cEEG software.
- Landmark validations from 2022–2023 are cited as context and were not pooled.
Extraction. For each study: device, signals, setting, reference standard, seizure group (convulsive and tonic seizures; focal; absence; mixed), detected/total seizures, false alarms and recording hours, validation scheme, and bias flags: self-grading (device-maker funding or staff, or evaluation of the authors' own algorithm or case set), device-maker involvement (yes / probable / unclear / no), other industry co-authors, and enriched sampling. Flags were coded from abstracts, affiliations and COI statements; 'probable' and 'unclear' are pending full text.
- When only a rate and hours were reported, false-alarm counts were approximated as rate × hours / 24. These are marked as approximations.
- When only an estimate and 95% CI were reported, the logit or log variance was derived from the CI.
Synthesis.
- Sensitivity: logit-transformed proportions, with a 0.5 continuity correction at 0 or 100%.
- FAR: log rate per 24 h, with variance 1/events. Sensitivity analysis: Poisson-normal generalized linear mixed model (random intercept, log-hours offset; maximum likelihood; t(k−1) Wald CI).
- Unit of analysis: sensitivity is event-level (seizures detected / seizures), and seizures are clustered within patients (e.g., Shah 2024 ambulatory arm: 10 seizures in 3 participants; Larsen 2024: 10 seizures in 3 patients). The binomial variance ignores this clustering and so overstates precision. Patients with seizures are listed per study in Table 1, and a sensitivity analysis excludes studies with 3 or fewer patients with seizures.
- Model-dependence check (wrist sensitivity): binomial-normal GLMM (random intercept on the logit; maximum likelihood; t(k−1) CI, t(k−2) PI), which uses the raw counts without a continuity correction.
- Model: REML between-study variance (τ²), with the HKSJ adjustment (truncated at max(1, q)) and t(k−1) confidence intervals. Prediction intervals used t(k−2). τ² and I² are reported; I² is computed from the fixed-effect Q (so it can be 0% while τ² > 0); I² derived from τ² is also given. Analyses used custom code in Python 3.13 with NumPy 2.5.4, SciPy 1.18.1 and statsmodels 0.15.0; figures were drawn with Matplotlib 3.11.2.
- Multi-arm studies: one arm per study, so no three-level model was needed. The pre-specified primary arm was used, and alternative arms were tested in sensitivity analyses, with one exception: for Shah 2024 the primary arm was changed after internal review from the ambulatory arm to the EMU arm, because the ambulatory arm's reference standard (caregiver report plus follow-up) does not meet the video-EEG/EEG/expert-video inclusion criterion. The ambulatory arm is now a sensitivity analysis only. Studies sharing a cohort (Zhang 2024 and Swinnen 2026, both SeizeIT2) were tested by exclusion.
- Bivariate model: a bivariate (Reitsma REML) sensitivity–specificity model was planned, but no modality had k≥4 studies with paired sensitivity and specificity, so it was not fitted.
- Robustness: leave-one-out analyses.
3. Results
3.1 Study flow (Figure 3)
- Identified: PubMed 468 unique records (232 from modality queries, 306 raw hits; 236 from targeted queries). OpenAlex 872, of which 706 remained after removing duplicates.
- Screened: 1,174 records by title/abstract; 1,021 excluded.
- Assessed for eligibility: 153 reports; 111 excluded (no event-level accuracy, no device validation, public-dataset-only, or out of date range). Reasons were not tallied per report (the screening log did not record a reason for each exclusion).
- Included: 42, shown as two boxes: 33 primary studies from 2024–2026 (synthesis) and 9 landmark or context reports (not pooled).
3.2 Pooled estimates (Figure 1)

| Modality / seizure group | k | Sensitivity, % (95% CI) | 95% PI | τ² | I² (fixed-effect Q) |
|---|---|---|---|---|---|
| Wrist/arm, convulsive and tonic seizures | 6 | 95.2 (86.4–98.4) | 82.2–98.9 | 0.08 | 0% (from τ²: 6%) |
| Wrist/arm, binomial-normal GLMM (model check) | 6 | 98.4 (80.8–99.9) | 47.2–100 | 1.23 | – |
| ECG/HRV, all seizures (descriptive only) | 4 | 81.3 (56.2–93.7) | 13.1–99.2 | 0.46 | 85% (from τ²: 81%) |
| ECG ± ACC, convulsive and tonic seizures (descriptive only) | 3 | 91.9 (39.9–99.5) | 0.0–100.0 | 0.63 | 41% (from τ²: 45%) |
| ECG/HRV, focal (descriptive only) | 3 | 71.6 (39.8–90.6) | 0.4–99.9 | 0.16 | 54% (from τ²: 54%) |
| Wearable/behind-the-ear EEG, all (descriptive only) | 3 | 87.2 (14.5–99.6) | 0.0–100.0 | 1.26 | 83% (from τ²: 92%) |
| Modality | k | FAR /24 h (95% CI) | 95% PI | τ² | I² (fixed-effect Q) |
|---|---|---|---|---|---|
| Wrist/arm, convulsive and tonic seizures (mostly in-hospital) | 5 | 0.108 (0.051–0.226) | 0.018–0.663 | 0.25 | 79% (from τ²: 86%) |
| ECG/HRV, all seizures (counts approximated except Alhaskir, pooled from reported median and CI) | 4 | 2.27 (0.072–71.8), not interpretable | not interpretable | 4.55 | 100% (from τ²: 100%) |
The ECG pools mix seizure types and devices: the all-seizure pool combines FBTCS-only data from a multimodal ECG+ACC shirt (Gharbi 2024) with FIAS-only data (St-Jean 2025), and Gharbi, St-Jean, Jahani and Wabi come from one centre, so cohorts may overlap. With ECG-only studies the convulsive pool would have k=2 and could not be pooled. The wearable-EEG pool mixes focal, convulsive and all-seizure data from different devices. These pools are therefore presented descriptively, with their wide CIs, and not as evidence of performance.
Sensitivity analyses.
- Binomial-normal GLMM (wrist sensitivity). 98.4% (80.8–99.9; PI 47.2–100; τ² 1.23). Under this model the prediction interval reaches below 50%, so a new setting cannot be assumed to reach >80%. The continuity-corrected REML estimate (95.2%) is pulled down by the 0.5 correction applied to the four studies at 100%.
- Excluding studies with ≤3 patients with seizures (Larsen 2024): REML 95.4% (83.7–98.8), k=5; GLMM 98.2% (77.6–99.9).
- Shah 2024 ambulatory arm (10/10 in 3 participants, caregiver-report reference; 31 false alarms over 6,735 h) instead of the EMU arm: sensitivity 94.9% (86.0–98.3; PI 83.5–98.6); GLMM 98.2% (81.5–99.8; PI 51.8–100); FAR 0.119/24 h (0.072–0.199). With the ambulatory arm, excluding the two ≤3-patient inputs gives GLMM 97.6% (71.6–99.9), k=4.
- Shah 2024 EMU FAR input. The primary analysis approximates the EMU false-alarm count from the reported rate (0.05/24 h × 4,279 h ≈ 8.9 events). Using the reported CI (0.02–0.08) instead gives 0.108/24 h (0.052–0.227).
- Poisson-normal model (wrist FAR). 0.096/24 h (0.074–0.125); 0.114/24 h (0.084–0.154) with the Shah ambulatory arm.
- Wearable EEG, Zhang 2024 EEG+EMG arm (43/44, 0.4/24 h) instead of EEG only: 87.1% (22.2–99.4).
- Excluding Wang 2025†: sensitivity 94.2% (82.7–98.2; GLMM 96.3%); FAR 0.108/24 h (0.035–0.333).
- Leave-one-out ranges. Wrist sensitivity 94.2–97.0% (GLMM 96.3–99.7%). Wrist FAR 0.092–0.125/24 h.
- Excluding Zhang 2024 (shared SeizeIT2 cohort) leaves wearable EEG at k=2: 79.5%, not interpretable.
- ECG FAR spans 0.25 to 30 per 24 h (I² 100%). The pooled value is shown for completeness and should not be interpreted.


3.3 Modality-by-modality evidence (Table 1)
| Modality | Study | Device / signals | Setting | Seizure group | Sensitivity | FAR | Notes | Patients with seizures |
|---|---|---|---|---|---|---|---|---|
| Wrist/arm | Vakilna 2024 [5] | Samsung Galaxy Watch research app; ACC+GYRO+PPG | EMU | convulsive and tonic seizures | 13/15‡ | 8/681 h (0.28/24 h)‡ | Sensitivity from leave-one-patient-out validation; false-alarm rate from a separate cohort without seizures | not stated (36 enrolled) |
| Wrist/arm | Jahani 2026 [1] | Embrace2; ACC+EDA | EMU | convulsive and tonic seizures | 16/16 | 29/8,952 h (0.08/24 h) | 3 of 19 seizures occurred while the device was not worn | not stated (72 enrolled) |
| Wrist/arm | Spahr 2025 [2] | research wristband; ACC | EMU, independent test | convulsive and tonic seizures | 47/49 | 169/31,479 h (0.13/24 h)‡ | 33 (test set, 347 enrolled) | |
| Wrist/arm | Wang 2025† [3] | research wristband; ACC+GYRO+sEMG | EMU + out-of-hospital | convulsive and tonic seizures | 60/60 | 0.107/24 h over 3,367 h | † see §3.4 | not stated (45 patients + 30 healthy controls) |
| Wrist/arm | Shah 2024 [4] | Apple Watch research app; ACC+PPG | EMU (primary arm) | convulsive and tonic seizures | 19/19 | 0.05/24 h (0.02–0.08) over 4,279 h (≈8.9 false alarms) | authors' own app; ambulatory arm (caregiver-report reference, not video-EEG) 10/10 in 3 participants, 31/6,735 h: sensitivity analysis only | EMU 15 (85 enrolled); ambulatory 3 (21 enrolled) |
| Wrist/arm | Larsen 2024 [6] | wrist movement sensor; ACC | EMU | tonic | 10/10 | 0.16/night | independent test set, 3 patients; device-maker co-author | 3 (+3 without seizures) |
| Upper arm (grouped with wrist/arm) | Dong 2026 [7] | upper-arm armband; ACC+PPG | home/residential | major motor | 76.2% (mean of folds) | 0.165/h | 10-fold CV; descriptive | n/r |
| Wrist | Faust 2025 [8]; Sourbron 2025 [9] | E4; AX6 | EMU; home | mixed | GTC recall 0.81; 64% (episodes >5 s) | – | segment-level / n=3 (Sourbron reference: visual annotation plus diaries; pharma co-authors); descriptive | n/r |
| ECG/HRV | Jeppesen 2025 [10] | wearable ECG + smartphone | EMU, phase 3 | all | 38/42 (90.5%); BTCS 19/19; focal 19/23 | mean 2.5/24 h (0 at night) | responders | 17 (101 enrolled) |
| ECG/HRV | Jeppesen 2024 [11] | wearable ECG | EMU | all | 50/59; GTC 25/26; focal 25/33 | 0.25/24 h | responders (>50 bpm) | 22 responders (34 total) |
| ECG multimodal | Gharbi 2024 [12] | connected shirt; ECG+ACC+resp | EMU | FBTCS | 56/66 | median 0.55/24 h, 8,067 h | 42 | |
| ECG multimodal | St-Jean 2025 [13] | connected shirt | EMU | focal (FIAS) | 71/113 | 30/24 h | 27 | |
| ECG/HRV | Alhaskir 2026 [14] | wearable ECG | EMU, LOPO | focal (FIAS) | median 66.6% | median 5.2/24 h (3.5–8.2), reported | 38 of 49 patients analysed (161 seizures after quality screening) | 38 analysed (49 enrolled) |
| ECG/HRV | Li 2025 [15] | ambulatory ECG | ambulatory | mixed | 72% (segment) | Sp 68% | descriptive | n/r |
| Behind-the-ear EEG | Swinnen 2026 [16] | Sensor Dot; bte-EEG+ECG | EMU, multicenter | focal | 0.73 (algorithm); 0.31 after review | precision 0.004 → 0.83 | 616 focal seizures, 192 patients | 192 enrolled |
| Behind-the-ear EEG | Zhang 2024 [17] | Sensor Dot | EMU | convulsive and tonic seizures | 44/44 (EEG alone) | 10.3/24 h; EEG+EMG 97.7% at 0.4/24 h; +ACC 90.9% at 0.1/24 h | SeizeIT2 subset | 27 |
| Reduced-channel EEG | Newton 2025 [18] | reduced-montage EEG | EMU + ambulatory | all | 86.2% (79.5–93.2); focal 77.3%; FBTC 91.4% | 0.162/h | device-maker co-authors | 31 (50 enrolled) |
| In-ear EEG | Joyner 2024 [19] | in-ear EEG | EMU | focal | 86.4% (expert review) | 0.1/24 h | human review, not algorithm | n/r |
| Behind-the-ear EEG | Swinnen 2024 [20] | Sensor Dot | home | absence | 0.84 (reviewed) | – | n/r | |
| Single-channel EEG | Renjith 2026 [21] | wearable 1-ch EEG | EMU | focal | 75% | 2.4/h | device-maker involvement probable (shares co-authors with Newton 2025); pending full text | n/r |
| Subscalp EEG | Park 2026 [22] | 2-ch subscalp | ultra-long-term | focal | 94% | 1.11/24 h | 16 patients; retrospective developer data split; device-maker co-author | 16 |
| Subscalp EEG | Munteanu 2026 [23]; van Norden 2026 [24] | subscalp | home | convulsive and tonic seizures; absence | 3/3 captured; spike-wave AUC 0.99 | – | descriptive | n/r |
| Subscalp EEG | Halliday 2025 [25]; Viana 2025 [26] | bilateral subscalp; subscalp | home | focal | 25/25 scalp seizures visible; 754 seizures, 52% unreported | – | signal capture / utility, not automated accuracy; Halliday: device-maker involvement probable; Viana: device-maker co-author | n/r |
| sEMG | Wabi 2026 [27] | dual miniaturized sEMG+ACC | EMU | convulsive and tonic seizures | 11/11 | 0.12/24 h (1,360 h); 0.06/24 h seizure-free | n/r | |
| Video | Boyne 2025 [28] | 3D-CNN video | EMU | convulsive and tonic seizures | 49/49 | 1.81/h | 36/49 videos with no false alarm | n/r |
| Audio-video | Wilms 2026 [29]; Andersson 2024 [31] | audio-video monitor | home | mixed | classification TC 150/152, tonic 102/186; yield 55% | 2.2% false positives | DS/LGS | n/r |
| Video AI | He 2026 [30] | vision-language model | EMU + home | mixed semiologies | 0.842–0.957 | 0.47–2.45% video-level | n/r | |
| Smartphone | Miron 2025 [32]; Kuperman 2026 [33] | smartphone video | home; clinic | spasms; absence | 82% (Sp 90%); 96% for ≥7 s | – | n/r | |
| Bed/mattress | none 2024–2026 with accuracy | – | – | – | – | – | context: under-mattress 16/23 convulsive (69.6%), 0.007/24 h [36] | n/r |
| Audio-only | none 2024–2026 | – | – | – | – | – | context: audio-video 93.7% major motor, 0.16/h [37] | n/r |
| Intracranial / RNS | none 2024–2026 with event-level sensitivity/FAR | – | – | – | – | – | context: deep-net RNS pattern detection [41] | n/r |
n/r: number of patients with seizures not reported in the abstract or not extracted. Sensitivity is per seizure; studies with few patients contribute clustered events.
‡ Not stated in the abstract and not verified against the full text (publisher access was blocked). These figures are consistent with the reported sensitivity and false-alarm rates.
Further context (2022–2023): wearable EEG for absence seizures, 78.8% per patient [34]; implanted cardiac monitor ECG, focal seizures 92.6% [35]; home arm-band in children, median 100% and 0.04/h [38]; multimodal patch for tonic seizures, 41% [39]; video motion clustering [40].
3.4 Wang 2025: resolution of the earlier conflict
The abstract reports 60/60 seizures and FAR 0.1070/24 h over 3,367.3 h (≈15 false alarms; the cohort includes 30 healthy controls). These figures match the extraction. The earlier discrepancy between abstract and full text could not be re-checked, because the full text was not open-access during this run. The study is therefore retained and flagged (†). Excluding it changes the wrist sensitivity by about 1 percentage point and leaves the FAR almost unchanged (§3.2).
3.5 Convulsive versus focal seizures
No study compared modalities head-to-head; differences across rows are confounded by seizure type, setting and population.
- Convulsive and tonic seizures: Wrist-motion devices reach ~95% (98% under the GLMM) for convulsive seizures, in small, mostly developer-run studies; other modalities have too few or too heterogeneous studies to say. Subscalp data are 3/3 signal capture only, the ECG ± ACC lower CI bound is 39.9%, and video runs at about 43 false alarms/24 h.
- Focal seizures: sensitivity falls to roughly 60–80%: ECG 71.6% (k=3), behind-the-ear EEG 0.73, reduced-channel EEG 77.3%, shirt 62.8% (71/113; per-patient mean 66%).
- False alarms in focal detection rise by one to two orders of magnitude. In one retrospective developer split, subscalp EEG reached 94% at 1.11 false alarms/24 h (temporal hold-out 87% at 5.9/24 h), about ten times the pooled wrist FAR (0.108/24 h), in a different population, seizure type and setting.
3.6 Conflict-of-interest and bias tally (Figure 4)

Under a self-grading definition (device-maker funding or staff, or evaluation of the authors' own algorithm or case set), 28 of 33 studies were self-graded, 4 were unclear and 1 (Jahani 2026) was independent. Device-maker staff were co-authors in 4 studies, probably in 2 more; other industry co-authors in 3.
- Device maker involved: confirmed in Larsen 2024, Newton 2025, Park 2026 and Viana 2025; probable in Renjith 2026 and Halliday 2025; unclear in 14; none in 13.
- Other industry (not the device maker): Sourbron 2025, Zhang 2024 and He 2026.
- Enriched samples: 5 (ECG responders, seizure-rich video sets, case–control smartphone videos, quality-screened ECG).
- Coding comes from abstracts, affiliations and COI statements; 'probable' and 'unclear' are pending full text.
Jahani 2026 is the only independent evaluation.
4. Discussion
Wrist/arm devices. For convulsive seizures, pooled wrist/arm sensitivity is high, but how consistent it is depends on the model. Under the continuity-corrected REML model, I² (fixed-effect Q) is 0% and the PI is 82–99%. Under the binomial-normal GLMM (98.4%, τ² 1.23), the PI extends to about 47%, so performance in a new setting is uncertain. All six studies are small, five are developer-run, and seizures are clustered within few patients in some of them. Pooled FAR is 0.11/24 h (mostly in-hospital), with a PI up to 0.66/24 h; a Poisson-normal model gives 0.096/24 h. These results are in line with the 2026 wearable meta-analysis [42], at a lower FAR. Enriched or selected samples (ECG heart-rate responders, seizure-rich video sets, case–control smartphone videos, quality-screened ECG) are likely to inflate sensitivity in those modalities (spectrum bias).
ECG. ECG adds value mainly for focal seizures with ictal tachycardia. The benefit depends on patient selection (heart-rate "responders"), which limits how far it generalises.
Behind-the-ear and reduced-channel EEG. These are the only non-invasive approaches with direct electrographic access. In the largest multicenter study, however, algorithm-only precision was very low (0.004); usable precision required human review.
Subscalp EEG. The 2024–2026 subscalp literature mostly demonstrates signal capture and clinical utility. Automated event-level accuracy is reported by a single study, so it remains an evidence gap.
Other modalities. Bed, audio-only and RNS detection have no 2024–2026 accuracy studies meeting the criteria.
Limitations.
- Single-agent rapid review with no human dual screening.
- Search scope: PubMed and OpenAlex only; Europe PMC was unavailable and Embase was not searched.
- 28 of 33 studies were self-graded; only Jahani 2026 is independent. COI coding is from abstracts and affiliations, pending full text.
- The ECG and wearable-EEG pools are descriptive only (mixed seizure types/devices, possible cohort overlap).
- Extraction was mostly from abstracts.
- Some FAR counts were approximated from rates. Spahr 2025 and Vakilna 2024 counts are unverified (‡).
- A sample of 11 extraction rows was cross-checked against PubMed and Crossref. No numeric errors were found; the COI and labelling corrections were applied, and COI coding was then redone for all 33 studies.
- The ECG FAR pool is not interpretable (I² 100%).
- With k=3, HKSJ intervals are, appropriately, very wide.
- Reference standards: all pooled inputs now use video-EEG or EEG. Shah 2024's ambulatory arm (caregiver report) was moved to a sensitivity analysis after internal review; this change of primary arm was not pre-specified.
- Unit of analysis: sensitivity is per seizure, and seizures cluster within patients (several studies have few patients with seizures; patient counts are often not reported), so the binomial intervals overstate precision.
- Model dependence: four of six wrist studies are at 100%, so the continuity-corrected estimate (95.2%) and the GLMM (98.4%, PI to ~47%) differ.
- Mixed settings and FAR inputs in the wrist pool: EMU recordings are pooled with Wang 2025 (EMU plus out-of-hospital, including 30 healthy controls in the FAR denominator), and Vakilna 2024's FAR comes from a separate seizure-free cohort. EMU false-alarm rates are not home false-alarm rates; the pooled FAR is mostly in-hospital.
- No study compared modalities head-to-head; differences across modalities are confounded by seizure type, setting and population.
- Validation schemes vary (cross-validation vs independent test sets).
- OpenAlex was sampled at the top 100 results per query.
- Publication bias could not be assessed at this k.
5. Conclusions
Wrist-motion devices reach ~95% or higher for convulsive seizures, at about 0.11 false alarms/24 h mostly in hospital, in small, mostly developer-run studies; other modalities have too few or too heterogeneous studies to say, and most evidence is developer-run. Focal-seizure detection is not mature in any non-invasive modality. Future validations should report event-level counts, recording hours, seizure-type-stratified results and independent test sets.
Credit. Prepared by Palo Alto Health Labs Co-Scientist. No funding. No human validation.
References
Years are journal issue years throughout.
- Jahani et al. Prospective evaluation of a seizure detection wearable device for timely interventions in an epilepsy monitoring unit. Epilepsia. 2026. https://doi.org/10.1002/epi.70082
- Spahr et al. Deep learning–based detection of generalized convulsive seizures using a wrist‐worn accelerometer. Epilepsia. 2025. https://doi.org/10.1111/epi.18406
- Wang et al. Seizure detection using the wristband accelerometer, gyroscope, and surface electromyogram signals based on in-hospital and out-of-hospital dataset. Seizure: European Journal of Epilepsy. 2025. https://doi.org/10.1016/j.seizure.2025.03.016
- Shah et al. Prospective multicenter study of continuous tonic-clonic seizure monitoring on Apple Watch in epilepsy monitoring units and ambulatory environments. Epilepsy & Behavior. 2024. https://doi.org/10.1016/j.yebeh.2024.109908
- Vakilna et al. Reliable detection of generalized convulsive seizures using an off‐the‐shelf digital watch: A multisite phase 2 study. Epilepsia. 2024. https://doi.org/10.1111/epi.17974
- Larsen et al. Automated detection of tonic seizures using wearable movement sensor and artificial neural network. Epilepsia. 2024. https://doi.org/10.1111/epi.18077
- Dong et al. Detection of nocturnal epileptic seizures using a wearable armband: A deep learning approach combining accelerometry and photoplethysmography signals. Computer Methods and Programs in Biomedicine. 2026. https://doi.org/10.1016/j.cmpb.2025.109087
- Faust et al. Detecting Diverse Seizure Types with Wrist-Worn Wearable Devices: A Comparison of Machine Learning Approaches. Sensors. 2025. https://doi.org/10.3390/s25175562
- Sourbron et al. Seizure quantification in sunflower syndrome by a wrist‐worn device. Epileptic Disorders. 2025. https://doi.org/10.1002/epd2.20318
- Jeppesen et al. Seizure detection using wearable electrocardiogram connected to a smartphone: a phase 3 clinical validation study. eBioMedicine. 2025. https://doi.org/10.1016/j.ebiom.2025.105952
- Jeppesen et al. Detection of seizures with ictal tachycardia, using heart rate variability and patient adaptive logistic regression machine learning methods: A hospital‐based validation study. Epileptic Disorders. 2024. https://doi.org/10.1002/epd2.20196
- Gharbi et al. Detection of focal to bilateral tonic–clonic seizures using a connected shirt. Epilepsia. 2024. https://doi.org/10.1111/epi.18021
- St‐Jean et al. Detection of focal impaired awareness seizures using a biometric shirt. Epilepsia Open. 2025. https://doi.org/10.1002/epi4.70099
- Alhaskir et al. Reliable detection of focal onset impaired awareness seizures in patients with epilepsy using wearable ECG: Development and validation study. Computer Methods and Programs in Biomedicine. 2026. https://doi.org/10.1016/j.cmpb.2026.109295
- Li et al. Epileptic seizure detection using heart rate variability from ambulatory ECG: a pseudoprospective study. Journal of Neural Engineering. 2025. https://doi.org/10.1088/1741-2552/adc33d
- Swinnen et al. A multicenter, video‐ EEG ‐based validation of a multimodal wearable device for focal seizure detection in adults: The SeizeIT2 study. Epilepsia Open. 2026. https://doi.org/10.1002/epi4.70260
- Zhang et al. Multimodal wearable EEG, EMG and accelerometry measurements improve the accuracy of tonic-clonic seizure detection. Physiological Measurement. 2024. https://doi.org/10.1088/1361-6579/ad4e94
- Newton et al. Validation of a discrete electrographic seizure detection algorithm for extended‐duration, reduced‐channel wearable EEG. Epilepsia. 2025. https://doi.org/10.1111/epi.18365
- Joyner et al. Using a standalone ear-EEG device for focal-onset seizure detection. Bioelectronic Medicine. 2024. https://doi.org/10.1186/s42234-023-00135-0
- Swinnen et al. Home recording of 3‐Hz spike–wave discharges in adults with absence epilepsy using the wearable Sensor Dot. Epilepsia. 2024. https://doi.org/10.1111/epi.17839
- Renjith et al. A Two-Stage Algorithm to Detect Electrographically Focal Seizures Using a Wearable Single-Channel EEG Sensor. IEEE Transactions on Biomedical Engineering. 2026. https://doi.org/10.1109/TBME.2026.3660806
- Park et al. Seizure detection using ultra‐long‐term subcutaneous electroencephalography: A deep learning CNN ‐ BiLSTM approach. Epilepsia. 2026. https://doi.org/10.1111/epi.18652
- Munteanu et al. Unilateral ultra long‐term subcutaneous EEG monitoring in drug‐refractory idiopathic generalized epilepsy. Epilepsia. 2026. https://doi.org/10.1111/epi.18644
- van Norden et al. Spike-wave detection in ultra-long-term EEG recordings from patients with absence seizures. Clinical Neurophysiology. 2026. https://doi.org/10.1016/j.clinph.2026.2111964
- Halliday et al. The UMPIRE study: A first‐in‐human multicenter trial of bilateral subscalp monitoring for epileptic seizure detection. Epilepsia. 2025. https://doi.org/10.1111/epi.18458
- Viana et al. Real‐world epilepsy monitoring with ultra‐long‐term subcutaneous electroencephalography: A 15‐month prospective study. Epilepsia. 2025. https://doi.org/10.1111/epi.18566
- Wabi et al. Detection of Bilateral Tonic-Clonic Seizures Using Miniaturized Wearable Electromyography-Accelerometry Sensors. IEEE Transactions on Biomedical Engineering. 2026. https://doi.org/10.1109/TBME.2025.3648668
- Boyne et al. Video‐based detection of tonic–clonic seizures using a three‐dimensional convolutional neural network. Epilepsia. 2025. https://doi.org/10.1111/epi.18381
- Wilms et al. Seizure classification using a multimodal seizure monitoring system (Nelli) in Dravet and Lennox–Gastaut syndromes: A non‐randomized, single‐center feasibility study. Epilepsia. 2026. https://doi.org/10.1111/epi.18640
- He et al. Towards generalizable seizure monitoring: EpiVLM for cross-environment detection and classification. npj Digital Medicine. 2026. https://doi.org/10.1038/s41746-026-02810-3
- Andersson et al. Video-based automatic seizure detection in pharmacoresistant epilepsy: A prospective exploratory study. Epilepsy & Behavior. 2024. https://doi.org/10.1016/j.yebeh.2024.110118
- Miron et al. Detection of epileptic spasms using foundational AI and smartphone videos. npj Digital Medicine. 2025. https://doi.org/10.1038/s41746-025-01773-1
- Kuperman et al. Novel Smartphone-Based Screening Tool for Absence Seizures in Pediatric Settings: A Comparative Study With Video EEG. Pediatric Neurology. 2026. https://doi.org/10.1016/j.pediatrneurol.2026.04.011
- Japaridze et al. Automated detection of absence seizures using a wearable electroencephalographic device: a phase 3 validation study and feasibility of automated behavioral testing. Epilepsia. 2023. https://doi.org/10.1111/epi.17200
- Jeppesen et al. Automated detection of focal seizures using subcutaneously implanted electrocardiographic device: A proof‐of‐concept study. Epilepsia. 2023. https://doi.org/10.1111/epi.17612
- Nouboue et al. Assessment of an under-mattress sensor as a seizure detection tool in an adult epilepsy monitoring unit. Seizure: European Journal of Epilepsy. 2023. https://doi.org/10.1016/j.seizure.2023.01.005
- Armand Larsen et al. Automated detection of nocturnal motor seizures using an audio‐video system. Brain and Behavior. 2022. https://doi.org/10.1002/brb3.2737
- van Westrhenen et al. Multimodal nocturnal seizure detection in children with epilepsy: A prospective, multicenter, long‐term, in‐home trial. Epilepsia. 2023. https://doi.org/10.1111/epi.17654
- Proost et al. Wearable detection of tonic seizures in childhood epilepsy: An exploratory cohort study. Epilepsia. 2023. https://doi.org/10.1111/epi.17756
- Ojanen et al. Automatic classification of hyperkinetic, tonic, and tonic-clonic seizures using unsupervised clustering of video signals. Frontiers in Neurology. 2023. https://doi.org/10.3389/fneur.2023.1270482
- Peterson et al. Deep net detection and onset prediction of electrographic seizure patterns in responsive neurostimulation. Epilepsia. 2023. https://doi.org/10.1111/epi.17666
- Mohamed et al. Automated seizure detection using wearable devices: updated systematic review and meta-analysis of tonic-clonic and focal seizure detection. Frontiers in Bioengineering and Biotechnology. 2026. https://doi.org/10.3389/fbioe.2026.1833080
Figures. Figure 1: forest plot of study-level and pooled sensitivity by modality (study CIs are exact Clopper–Pearson; Shah 2024 shown with its EMU arm). Figure 2: bubble plot of sensitivity against false-alarm rate per 24 h, by modality. Figure 3: PRISMA study-flow diagram. Figure 4: conflict-of-interest and self-grading tally by modality.
Corrections
None yet.
Found an error? Email hello@paloaltohealthlabs.com.
More from the Palo Alto Health Labs Co-Scientist · All posts
Have your own questions? Sign up for the Beta
Tell us the health AI or digital health question you would want the Co-Scientist to review, and join the beta list.
Scope it in 30 minutes
Book a scoping call and we'll name the smallest engagement that moves you forward. Most teams start with the fixed-scope Initial Audit.
Book a 30-min scoping callPrefer to write? Send a short note.